🚪 Premium Commercial Doors – Fire Rated, Metal, Solid Core Wood & More 📦 Statewide Delivery – Direct to Your Jobsite or Business Across Florida ⚡ Priority Pricing & Fast Shipping – Get the Best Value Without Delays
Why Choose YK?
✅ Certified Quality – UL, CE, WH, 3C & More – Fully Compliant & Trusted ✅ Dedicated Account Manager & Expert Support ✅ Complete Packages – Doors, Frames & Hardware in One Order ✅ Job-Site Delivery & Quick-Ship Options for Urgent Projects
Serving Florida with Quality & Reliability – Contact Us Today!
YK Fire Door – Your Trusted Partner for Fire Rated Door& Commercial Doors in Florida
🔥 Expertise You Can Trust – With Years of Florida-Specific Experience, We Know Local Fire Codes & Inspections
🚪 Wide Selection – Fire Rated Doors, Steel & Wood Doors, Frames, Hardware & More 📦 Fast & Reliable – In-Stock, Quick-Ship & Custom Options – Statewide Florida Delivery 💰 Competitive Pricing – Get a Quote Today & Save
Why Contractors & Businesses Choose YK Fire Door? ✅ Florida-Proven Compliance – Certified Solutions That Pass Inspections ✅ End-to-End Support – From Selection to Installation ✅ Trusted Since 1995 – Local Expertise, National Standards
Serving All of Florida – Contact Us for a Seamless Door Ordering Experience!
Ola Nordmann
Customer Support
Lorem ipsum..
Work With a Qualified Fire Door & Commercial Door Professional Work one-on-one with an experienced specialist in fire-rated doors, commercial metal doors, wood doors, hollow metal frames, and door hardware. Get expert guidance on selecting, customizing, and installing certified fire doors and commercial door solutions for your project.
Ola Nordmann
Customer Support
Lorem ipsum..
Save Time, Money & Avoid Costly Mistakes We provide customized fire door and commercial door solutions worldwide, delivering quality products, safety compliance, and expert support for efficient, cost-effective projects across Asia, Europe, the Americas, and Africa.
Ola Nordmann
Customer Support
Lorem ipsum..
Efficient Delivery & Freight Discounts on Most Orders We provide fast, reliable delivery tailored to your project requirements. Our team ensures efficient transport to your specified location worldwide, with volume pricing and flexible shipping solutions. Contact us for details.
YK Fire Door – Florida’s Premier Fire-Rated Building Solutions Comprehensive Fire Protection for Every Construction Need
From solid-core fire-rated wood doors to durable steel fire doors, expansive fire-rated glass systems, and specialized fireproof building materials – YK Fire Door delivers code-compliant solutions for commercial buildings, healthcare facilities, schools, and multi-family housing across Florida.
Key Differentiators: • Florida-specific fire code expertise • UL-certified & ASTM-tested products • Custom configurations for unique architectural needs
Local Commercial Door Specialists – Your Project Partners
With the largest team of certified fire door professionals in the region, we provide: ✓ Complete commercial door system audits ✓ Fire code compliance consulting ✓ Precision installation by licensed technicians ✓ Ongoing maintenance programs
Florida Fire Door Policy & Qualification Requirements (2025)
1. Regulatory Framework and Applicable Standards
In Florida, fire doors fall under the Florida Building Code (FBC), which embeds key components from the International Building Code (IBC) and outlines strict requirements from NFPA 80 (Installation and Maintenance of Fire Doors). Each component—door, frame, hardware—must meet recognized performance standards:
1. UL 10B and UL 10C test assemblies for fire-resistance under neutral and positive pressure. 2. NFPA 252 is still accepted for legacy frames in existing buildings. 3. NFPA 105 governs smoke-door assemblies—common in corridors and stairwells. 4. Since 2020, all fire-rated door assemblies must come complete from the factory with certification.
Inspection is enforced by local fire marshals and certified fire door inspection companies during construction and annually thereafter. For project teams and owners, understanding this full suite of certification standards is essential for passing inspections and avoiding costly hold-ups.
2. Fire Resistance Ratings by Application
Florida classifies fire doors by rating—measured in minutes—for their ability to contain heat, flames, and pressure. This table reflects typical applications:
Application Type
Rated Duration
Common Door Style
Multi-family housing (apartments)
20–45 minutes
Wood fire doors with UL 10B
Daycares, schools
60 minutes
Steel fire-rated doors
Hospitals, long-term care facilities
90 minutes
Commercial fire doors, steel
High-rise buildings & mixed-use towers
90–180 minutes
Rolling fire shutters, steel
Stairwells & exit corridors
90+ minutes
Hollow metal, fire-rated glass
To avoid inspection delays, fire doors must display visible UL labels indicating their exact rating. No field modifications are allowed—anything from cutting a new vision panel to swapping hardware voids certification.
Only UL, Intertek (WH), or FM Approved fire door assemblies are accepted.
Labels must remain visible after installation—covering, painting, or replacing labels is strictly prohibited.
Annual NFPA 80 inspections are mandatory—failure leads to citations and possibly insurance complications.
Self-closing mechanisms are non-negotiable—they must activate automatically and close the door fully during a fire.
Fire safety hinges not only on supply but also on follow-through: installing, labeling, and maintaining fire doors correctly.
4. Installation & Maintenance Best Practices
Proven practices come from experience:
Inspection teams and maintenance crews should always:
Install each door strictly per the manufacturer’s rated assembly instructions
Perform monthly function tests, including release under fire alarm and full closure
Replace worn seals and ensure panic bars are working without delay
Never attempt field modifications. Installing non-rated hardware, drilling or cutting, requires full re-testing. This is not a workaround—it’s a code violation that leads to project delays or legal breaches.
5. Market Trends: Fire and Hurricane Resistance
Florida’s coastal regions demand dual functionality: fire protection and hurricane impact resistance. Projects in Miami-Dade and Broward counties often require doors that are:
Dual-certified: with both UL/Factory Mutual and Miami-Dade NOA (Notice of Acceptance)
Resistant to high wind and missile impact, while still providing fire integrity
This is a growing niche in the commercial fire doors market: building owners want one door that meets multiple performance thresholds.
6. YK Fire Door Company in Action
Jacksonville General Hospital Expansion (2025)
Product delivered: 180 90-minute rated steel fire doors, UL 10C certified, complete with panic hardware and smoke seals
Installation oversaw: Every door was installed under YK’s quality control, with UL labels verified by certified inspectors
Outcome: Zero inspection punch-list items; doors passed permit inspection immediately; final occupancy was granted in record time
Bonus compliance: YK coordinated with fire door inspection companies to ensure seamless administration of NFPA 80 maintenance plans
This case demonstrates YK Fire Door Company’s expertise as a fire door manufacturer, supplier, installer, and maintenance partner—all in compliance with updated Florida code demands.